Prolink Pro 701 UPS
Warranty:
01 year Warranty for ups battery ,
2 Years Warranty for ups Circuit
Key Features & Benefits
- Boost and Buck TRUE AVR for Voltage Stabilization
– automatically regulating and smoothing the power supply from voltage fluctuations (140-300V) to better protect your equipment with a constant voltage. - Fast Battery Charging
– gain 90% capacity after 4-6hours of recharging - Auto Restart while AC is Recovering
– alleviate sudden and temporary power outages and restart automatically while AC power supply is recovering - Cold Start Function (DC power on) and Off-mode Charging
- Wide Input Voltage range and compatible with small generators
****Do not Use this UPS with a Internet Router, Oxygen Motor or any 12V, 9V, 5V Power Adapter support Units.*********
****Use this UPS Only With Computer.****
*For Warranty Claim UPS Backup Time Need to Below 8 Minutes Only.
*Before Use Please Charge UPS 8 Hours.
*Don’t use UPS Backup time Until Automatic Shutdown. (When you hear a Continues Beep Sound, please off your UPS)
*Do Not Open UPS with in Warranty Period. (No Warranty if you Open a UPS)
*We Are Not Recommend to Use a UPS for Small Amount Power Units.
(ex-Internet Routers, Oxygen Motor…….)
PROLiNK Line Interactive UPS 650VA
GENERAL
Capacity | 650VA |
Dimension (mm) | 286 x 96 x 138 (D x W x H) |
Weight (kg) | 4.3 |
INPUT
Voltage Range | 162 ~ 290VAC (Single boost)140 ~ 300VAC (Double boost) |
Frequency | 50Hz/60Hz (Auto-sensing) |
Phase | Single + GND |
OUTPUT
Voltage Range | 220-240VAC |
Battery Mode | 220-240VAC |
Frequency | 50Hz ±1% (Battery mode) |
Waveform | Simulated sine wave (Battery mode)Sine wave (AC mode) |
Transfer Time | 2ms typical |
BATTERY
Type | 12V/8.2AH x 1 |
Backup Time | 8 – 20 mins depending on load |
Recharge Time | 2-4 hours recover to 90% capacity |
INTERFACE & INDICATORS
Display | LED/LCD Optional |
Alarm | Batt. Mode, low battery, overload, fault, etc. |
PROTECTION/MONITORING
Short Circuit Protection | Yes (Line mode & battery mode) |
Surge Protection | Yes |
Alarm | Audible & Visual |
Overload Protection | Line mode : 100 – 120% 1 min change to fault mode >120% change to fault mode immediatelyBattery mode : 100 – 120% 1 min change to fault mode >120% change to fault mode immediately |
Intelligent Battery | Prevent overcharging of battery |
Management | Protect battery and prolong battery life |
Real Panel
1. AC Mode Indicator Green LED Lighting
2. Battery Mode Indicator Battery Normal : Yellow LED Lighting and Blinking every 30s 3. Overload and Fault Indicator Overload : Red LED Blinking every 2s 4. Power Switch 5. Power AC Input 6. Backup Outlets |